BRK 790MBX Mains Powered Hard Wired Heat Alarm with 9V Battery Back-up

(3 customer reviews)

£21.55 Ex VAT

Out of stock

Description

BRK 790MBX Mains Powered Hard Wired Heat Alarm with 9V Battery Back-up

Mains powered hard wired heat alarm with 9V alkaline battery back up and a PUSH-FIT docking base system; designed to ensure quick and easy installation of base unit to the mains feed supply at installation stage (1st fix) and for quick and easy connection of alarm to base unit (2nd fix). The PUSH-FIT base provides spacious room for wiring in premises such as flats where concrete ceilings can be problematic. Top and side entries accommodate for either cable or mini trunking installations.

These alarms can be installed, along with linked smoke alarms, to provide a fire detection system to comply with British Standard BS 5839: Pt.6 Grade D “System incorporating one or more interlinked mains powered smoke alarms (and heat alarms if required), each with an integral stand-by supply. The interlink can be hardwired or radio-interlinked”.

Heat alarm are normally used in locations where the use of a smoke alarm would give rise to nuisance alarms, e.g. Kitchen, Garage, Boiler Rooms, Lofts etc.  Heat Alarms should not be used as the sole fire protection method and should only be used in conjunction with Smoke Alarms.

  • 230V hard wired mains powered heat detector / alarm
  • 9V alkaline battery back-up (included)
  • PUSH-FIT docking base. No separate pattress plate required
  • Advanced Class A2 thermistor sensing technology. Activates in range of +54°C to +70°C
  • Test and silence button
  • Low battery warning
  • Multi-alarm interlink (up to 12 smoke and heat units from list below)
  • Compatible with DS700RF wireless interlink base
  • LED operating indicators
  • 85db alarm
  • 5 year guarantee
  • BS EN14604: 2005 standard
  • CE mark

Dimensions: 142mm diameter x 70mm deep

Compatible devices in this range:

770MBX – Ionisation Smoke Alarm
760MBX – Optical Smoke Alarm
DS700RF – Wireless Interlink Base

Multi-alarm interlink:-

When more than one alarm is installed within the same building these should be connected together so that if one alarm is activated , all alarms sound.

The normal wiring method for these alarms is 6242Y 1 or 1.5mm (twin & earth) from the power supply, which can be either a dedicated circuit at the consumer unit or a local normally used lighting circuit, to the first alarm position then 6243Y 1 or 1.5mm (3 core & earth) from the first alarm to the second alarm and so on. The maximum circuit length is 250 metres.

Alternatively you can use the DS700RF Wireless Interlink Base to replace the interlink. Please note that when using interlink bases a permanent power supply is still required to each alarm position (using 6242Y 1 or 1.5mm twin & earth cable).

Replacement models:-

This model replaces the BRK 680MBX which is now out of production.

3 reviews for BRK 790MBX Mains Powered Hard Wired Heat Alarm with 9V Battery Back-up

  1. zortilonrel

    I’d have to examine with you here. Which is not one thing I usually do! I take pleasure in reading a post that may make folks think. Additionally, thanks for permitting me to comment!

  2. Mariana

    Everything is very open with a very clear description of the issues.
    It was really informative. Your website is very useful.

    Thank you for sharing!

    Look at my webpage … an asmr

  3. Brent

    Amazing! This blog looks just like my old one! It’s on a completely different topic but it has pretty much the same page layout
    and design. Great choice of colors!

    Here is my site – info that – http://bitly.com/3EEHZyo,

Add a review